Mary C.

Mary C.

I found that the furnace had overheated and was throwing a high limit error code "33." I reduced gas pressure and increased fan speed and removed some drywall blockage. System is operational at time of departure.

Near Asbury Ct, Xenia, OH 45385
Xenia, OH - I found that the furnace had overheated and was throwing a high limit error code "33." I reduced gas pressure and increased fan speed and removed some drywall blockage. System is operational at time of departure.
Tara L.

Tara L.

I performed a tune up on a Lennox gas furnace

Near Prestonwood Ct N, Xenia, OH 45385
Xenia, OH - I performed a tune up on a Lennox gas furnace
Tiffanie W.

Tiffanie W.

I am Performing our Five Star Tune-Up & Safety Check on a 2020 Carrier Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.

Near Industrial Blvd, Xenia, OH 45385
Xenia, OH - 	I am Performing our Five Star Tune-Up & Safety Check on a 2020 Carrier  Gas Furnace. All readings were within manufacturer's specifications, unit operating properly at this time.
Josh A.

Josh A.

Upon tune up inspection for 2013 Carrier furnace, everything running properly. Unit operational at time of departure.

Near Xenia, OH 45385
Xenia, OH - Upon tune up inspection for 2013 Carrier furnace, everything running properly. Unit operational at time of departure.
Josh A.

Josh A.

Upon arrival power was off to 2006 Goodman furnace, turned on and called for heat at thermostat and fault code 3 pressure switch, Tested system it's rated to close at .35 inwc and it's good, Tested inducer motor it's over amping, it is pulling 1.10 inwc enough to close switch, The circuit board is bad and needs replaced, also recommend replacing inducer motor due to it over amping, System not operational at departure.

Near Xenia, OH 45385
Xenia, OH - Upon arrival power was off to 2006 Goodman furnace, turned on and called for heat at thermostat and fault code 3 pressure switch, Tested system it's rated to close at .35 inwc and it's good, Tested inducer motor it's over amping, it is pulling 1.10 inwc enough to close switch, The circuit board is bad and needs replaced, also recommend replacing inducer motor due to it over amping, System not operational at departure.
Jacob O.

Jacob O.

I installed a new Carrier 13 SEER 2.5 Ton Air Conditioner

Near N Monroe Dr, Xenia, OH 45385
Xenia, OH - I installed a new Carrier 13 SEER 2.5 Ton Air Conditioner
Josh A.

Josh A.

Reset fan speed on Five Star furnace. All is operating properly at this time.

Near Xenia, OH 45385
Xenia, OH - Reset fan speed on Five Star furnace. All is operating properly at this time.
Josh A.

Josh A.

Furnace repair

Near Xenia, OH 45385
Xenia, OH - Furnace repair
Aaron W.

Aaron W.

Performed complete tuneup and safety inspection on a Lennox furnace to ensure efficient operation for the winter season of 2019/2020.

Near Xenia, OH 45385
Xenia, OH - Performed complete tuneup and safety inspection on a Lennox furnace to ensure efficient 
operation for the winter season of 2019/2020.
Nearby N.

Nearby N.

Near W 2nd St, Xenia, OH 45385